Data Design
LMU/COICP Example
Data Design Example
Define LMU/COICP data structures with realistic synthetic records, evidence-event examples, reviewer-role assignments, review package contents, scope warnings, and deferred AI draft structures.
ES-105
Data Design
Evidence Structures
Project
LMU Campus Operations and Incident Coordination Platform
Document control
| Field |
Value |
| Artifact owner |
COICP Product Engineer |
| Primary reviewers |
Architecture Review Board chair, IT security reviewer, AI reviewer, Compliance reviewer, Campus Safety liaison |
| Status |
Accepted for ES-105 design baseline |
| Last updated |
2026-07-06 |
| Related Engineering Stage |
ES-105 — Design |
| Project workspace target |
docs/project-workspace/design/data_design.md |
Design context
| Field |
Value |
| Source architecture package |
ES-104 — Architecture |
| Design baseline produced |
LMU-COICP-DES-001 |
| Implementation baseline expected next |
LMU-COICP-IMPL-001 |
| Integrated baseline expected later |
LMU-COICP-INT-001 |
| Release candidate expected later |
LMU-COICP-RC-001 |
| Downstream release posture |
Internal engineering review only |
| Planned downstream review environment |
LMU-COICP Internal Engineering Review Environment |
| Planned downstream dataset |
Spring Semester Synthetic Incident Dataset |
| Planned downstream synthetic records |
421 |
| Planned downstream reviewer accounts |
24 |
| Planned downstream review window |
March 18–22, 2026 |
| AI Incident Summary |
Deferred / disabled |
| Operational pilot |
Not approved |
Entity register
| Entity |
Purpose |
Example |
IncidentRecord |
Current synthetic incident coordination state |
LMU-INC-SYN-118 Damen Hall water leak |
EvidenceEvent |
Timestamped record of key action |
HANDOFF_RECORDED from Campus Operations to Facilities |
RoleAssignment |
Reviewer-role and scenario scope |
Residence Life reviewer assigned to COICP-SYN-204 |
ScopeWarningEvent |
Out-of-scope or emergency-boundary warning |
COICP-SYN-322 blocked emergency-related entry |
ReviewPackage |
Future view/export of incident evidence |
ARB package for COICP-SYN-118 |
AISummaryDraft |
Future AI-generated draft, disabled for RC-001 |
not created in RC-001 |
Example IncidentRecord
{
"incident_id": "LMU-INC-SYN-118",
"scenario_id": "COICP-SYN-118",
"category": "Facilities - Water / Leak",
"location": "Damen Hall, Multipurpose Room corridor",
"description": "Water leak reported near event setup area before evening student organization meeting.",
"status": "Assigned",
"owner_group": "Facilities Coordination",
"created_by_role": "Campus Operations Reviewer",
"data_classification": "Synthetic internal-review record",
"ai_summary_enabled": false
}
Example EvidenceEvent
{
"event_id": "EVT-LMU-SYN-118-003",
"incident_id": "LMU-INC-SYN-118",
"scenario_id": "COICP-SYN-118",
"event_type": "HANDOFF_RECORDED",
"actor_role": "Campus Operations Reviewer",
"payload": {
"previous_owner": "Campus Operations",
"new_owner": "Facilities Coordination",
"previous_status": "Open",
"new_status": "Assigned"
},
"correlation_id": "CORR-LMU-SYN-118-HANDOFF-001"
}
Example ScopeWarningEvent
{
"event_id": "EVT-LMU-SYN-322-SCOPE-001",
"scenario_id": "COICP-SYN-322",
"actor_role": "Campus Safety Liaison",
"category_attempted": "Emergency Safety Concern",
"decision": "blocked",
"normal_incident_created": false
}
Downstream verification fields
| Field / Behavior |
Verification Route |
EvidenceEvent created on incident creation |
ES-107 implementation / ES-109 TC-001 |
EvidenceEvent created on handoff |
ES-107 implementation / ES-109 TC-005 |
| evidence write failure blocks state change |
ES-109 TC-007 / DEF-003 |
| role-based denial hides protected detail |
ES-109 TC-011 / DEF-002 |
| AI summary disabled flag remains false |
ES-109 AI verification |
| emergency-related scope warning blocks normal incident |
ES-109 TC-012 / DEF-004 |
Continue to Workflow Design
Define LMU-specific normal, alternate, deferred, and exception workflows.
Open Workflow Design →