Skip to content

Verification Matrix

LMU/COICP Example

Verification Matrix Example

Map LMU/COICP requirements, guardrails, risks, test cases, execution results, evidence records, remaining gaps, owners, and release-readiness implications.

ES-109 Matrix LMU Coverage

Example purpose

This artifact records ES-109 verification coverage.

It makes clear what was verified, what was partially verified, what failed, and what remains unverified before ES-110 Release Readiness.

Project

LMU Campus Operations and Incident Coordination Platform

Document control

Field Value
Artifact owner COICP Product Engineer
Primary reviewers Architecture Review Board chair, IT security reviewer, AI reviewer, Compliance reviewer, Campus Safety liaison
Status Accepted with visible gaps
Last updated 2026-07-06
Related Engineering Stage ES-109 — Testing and Verification
Project workspace target docs/project-workspace/testing/verification_matrix.md

Testing context

Field Value
Integrated baseline under test LMU-COICP-INT-001
Candidate produced by testing LMU-COICP-RC-001
Target release posture Internal engineering review only
Planned review environment LMU-COICP Internal Engineering Review Environment
Planned dataset Spring Semester Synthetic Incident Dataset
Planned synthetic records 421
Planned reviewer accounts 24
Planned review window March 18–22, 2026
AI Incident Summary Deferred / disabled
Operational pilot Not approved

Verification matrix

Requirement / Guardrail / Risk Verification Method Test Case(s) Result Evidence Gap / Release Implication
FR-001 Create incident Integration test TC-001, TC-002 Pass test_execution_record.md none for internal review
FR-003 Update status Integration test TC-005, TC-006 Partial / fail test_execution_record.md DEF-001 blocks pilot
FR-005 Preserve status history Guardrail verification TC-001, TC-005, TC-007 Partial guardrail_verification.md DEF-003 blocks pilot
FR-006 Role-based access Access test TC-004, TC-011 Partial test_execution_record.md DEF-002 blocks real-user pilot
FR-008 AI review before official summary Review inspection TC-008 Pass ai_verification_record.md AI disabled only
NFR-001 Auditability Guardrail/failure-path verification TC-001, TC-005, TC-007 Partial guardrail_verification.md evidence failure behavior unverified
NFR-002 Access control Access test TC-004, TC-011 Partial test_execution_record.md limited role set only
C-001 No emergency dispatch replacement Scope-boundary test TC-012 Planned / partial test_execution_record.md DEF-004 requires focus
C-005 Pilot category scope Integration test TC-003 Pass test_execution_record.md none for internal review
G-001 Evidence event for official state change Guardrail verification TC-001, TC-005, TC-007 Partial guardrail_verification.md failure path open
G-002 AI output not official without human review AI verification TC-008 Pass ai_verification_record.md none for disabled AI
G-003 Protected actions require access check Access test TC-004, TC-011 Partial test_execution_record.md full matrix pending
G-004 Emergency/out-of-scope not normal workflow Integration test TC-003, TC-012 Pass / partial test_execution_record.md emergency-specific test must be formalized
G-005 Retention not hard-coded Review inspection TC-010 Pass regression_check_record.md final retention policy pending
G-006 Direct updates do not bypass evidence Review / integration TC-005, TC-007 Partial guardrail_verification.md evidence failure path open

Unverified or incomplete areas

Area Status Reason
Full post-incident review export Deferred Not in first core workflow increment.
Full AI Incident Summary workflow Deferred AI feature intentionally disabled.
Enterprise identity integration Out of scope Internal review will use approved reviewer accounts only.
Final retention enforcement Deferred / governance Retention policy unresolved.
Complete evidence write failure handling Unverified TC-007 blocked/incomplete.
Full access-control role matrix Partial TC-004 / TC-011 limited.
Formal emergency-boundary verification Partial Campus Safety scenario requires focused follow-up.

Coverage decision

The matrix supports moving to ES-110 release-readiness evaluation because coverage gaps are visible and owned.

The matrix does not support operational pilot approval.

Continue to Test Execution Record

Record pass, fail, partial, and blocked test results.