Skip to content

Workflow Design

LMU/COICP Example

Workflow Design Example

Define LMU/COICP workflows using concrete scenarios for incident creation, Facilities handoff, Residence Life visibility, HVAC closure, emergency-boundary rejection, deferred AI summary, and future review package generation.

ES-105 Workflow Behavior Design

Project

LMU Campus Operations and Incident Coordination Platform

Document control

Field Value
Artifact owner COICP Product Engineer
Primary reviewers Architecture Review Board chair, IT security reviewer, AI reviewer, Compliance reviewer, Campus Safety liaison
Status Accepted for ES-105 design baseline
Last updated 2026-07-06
Related Engineering Stage ES-105 — Design
Project workspace target docs/project-workspace/design/workflow_design.md

Design context

Field Value
Source architecture package ES-104 — Architecture
Design baseline produced LMU-COICP-DES-001
Implementation baseline expected next LMU-COICP-IMPL-001
Integrated baseline expected later LMU-COICP-INT-001
Release candidate expected later LMU-COICP-RC-001
Downstream release posture Internal engineering review only
Planned downstream review environment LMU-COICP Internal Engineering Review Environment
Planned downstream dataset Spring Semester Synthetic Incident Dataset
Planned downstream synthetic records 421
Planned downstream reviewer accounts 24
Planned downstream review window March 18–22, 2026
AI Incident Summary Deferred / disabled
Operational pilot Not approved

Workflow register

ID Workflow Example Scenario Actors Evidence Produced RC-001 Status
WF-001 Create synthetic incident COICP-SYN-001 Information Commons leak Campus Operations reviewer INCIDENT_CREATED In scope
WF-002 Handoff to responsible group COICP-SYN-118 Damen Hall water leak Campus Operations → Facilities OWNER_CHANGED, HANDOFF_RECORDED In scope, partial
WF-003 Role-sensitive scenario review COICP-SYN-204 Mertz Hall door access issue Residence Life reviewer NOTE_ADDED if authorized In scope
WF-004 Closure with rationale COICP-SYN-219 Cudahy Science HVAC outage Facilities reviewer INCIDENT_CLOSED In scope, limited
WF-005 Emergency-boundary rejection COICP-SYN-322 emergency-related safety concern Campus Safety liaison SCOPE_WARNING if configured In scope
WF-006 AI draft summary Future COICP-SYN-118 summary Future authorized reviewer disabled Deferred / disabled

WF-002 — Handoff to Facilities

Campus Operations routes COICP-SYN-118 Damen Hall water leak to Facilities before an evening student organization event. The system verifies handoff permission, validates transition from Open to Assigned, updates owner to Facilities Coordination, and records STATUS_CHANGED, OWNER_CHANGED, and HANDOFF_RECORDED.

If any required evidence event cannot be written, the official handoff must fail safely. This becomes DEF-003 downstream if not verified.

WF-003 — Residence Life role-sensitive review

Residence Life reviews COICP-SYN-204 Mertz Hall exterior door access issue. The reviewer can view assigned residence scenario details and add an authorized note, but cannot export the full review package or modify unrelated Facilities scenarios. This drives ES-109 access-control tests and DEF-002 if matrix coverage is incomplete.

WF-004 — Closure with rationale

Facilities closes COICP-SYN-219 Cudahy Science HVAC outage after temporary cooling is restored and evening classroom impact is mitigated. Closure requires rationale and creates INCIDENT_CLOSED. Invalid direct jump from Open to Closed without required rationale is rejected and maps to DEF-001 if inconsistent.

WF-005 — Emergency-boundary rejection

Campus Safety tests COICP-SYN-322. The system blocks normal incident creation, displays existing emergency-procedure guidance, and may record SCOPE_WARNING. No normal IncidentRecord is created. This maps to ES-109 TC-012 and DEF-004 if not formalized.

Continue to Access-Control Design

Define reviewer roles, protected actions, scenario-specific visibility, denied behavior, and access-test implications.